- Model / Series
- SY4860A
- Product Dimensions
- 183 × 196 × 70 mm
- Controller Type
- PWM
- System Voltages
- 12 / 24 / 36 / 48 V (automatic recognition)
- Rated Charge Current
- 60 A
- Current Filter Band
- 41A-60A
- Maximum PV Open-Circuit Voltage
- 100 V VOC maximum
- Supported Battery Types
- Lead-acid, LiFePO4 and lithium-ion; configure charging settings
SY4860A: 60 A PWM charging with adjustable battery settings
The 60 A entry in the SY-A range for off-grid battery charging and timer-controlled DC lighting. Choose it when the system current fits the 60 A model rather than selecting a larger controller solely by enclosure size.
This page describes the PWM configuration shown in the product photographs. The wider SY-A catalog also contains differently marked illustrations; confirm the ordered controller version rather than identifying the charging method from the series name alone.
Practical features
- 60 A rated charging current with automatic 12 / 24 / 36 / 48 V system recognition.
- Display and push buttons for monitoring and configuration.
- Adjustable battery voltage thresholds for the specified battery chemistry.
- Light/timer load control and manual load switching.
- 5 V / 2 A USB output and an aluminum heat-dissipation back plate.
Technical specifications
| Model | SY4860A |
|---|---|
| Controller version | PWM (matching the photographed units) |
| Rated charging current | 60 A |
| Rated load current | 60 A (catalog rating; installation limits apply) |
| Battery system voltage | 12 / 24 / 36 / 48 V, automatic recognition |
| Maximum PV open-circuit voltage | 100 V VOC |
| Battery types | Lead-acid, LiFePO4 and lithium-ion; confirm and configure the charging settings |
| Full-charge cutoff defaults | 14.2 / 28.4 / 42.6 / 56.8 V for 12 / 24 / 36 / 48 V systems; adjustable |
| Low-voltage disconnect defaults | 9.5 / 19 / 28.5 / 38 V for 12 / 24 / 36 / 48 V systems; adjustable |
| USB output | 5 V / 2 A |
| Load operation | Light control with timer, or manual switching |
| Thermal protection | MOS temperature above 85°C |
| Working temperature | −10°C to +45°C |
| Protection rating | IP21 |
| Dimensions | 183 × 196 × 70 mm |
| Net weight | 655 g |
PV and battery matching
The 100 V figure is the maximum PV open-circuit voltage, not an MPPT operating range and not permission to use any panel string with any battery. The catalog recommends panel voltage selections of 15–23 V for a 12 V battery, 30–46 V for 24 V, 45–66 V for 36 V and 60–90 V for 48 V. Confirm the array specification, including open-circuit voltage under the actual conditions, before connection.
Do not connect a higher-voltage battery-system array to a lower-voltage battery just because its voltage is below the absolute PV ceiling. The catalog recommends keeping PV loading within 80% of the controller rated loading for stable operation; ask for model-specific array sizing.
Installation and environment
Follow the supplied instructions: connect the battery first, then PV, then the DC load. For first connection the catalog requires battery voltage above 10 / 20 / 30 / 40 V for the corresponding 12 / 24 / 36 / 48 V system. Check the recognized voltage before proceeding. IP21 is not a weatherproof outdoor enclosure rating; protect the controller from rain and provide ventilation.
Choosing within SY-A
SY4860A provides 60 A rated charge current and weighs 655 g. SY4860A, SY4880A and SY48100A share the listed enclosure dimensions but are separate 60 A, 80 A and 100 A models. Current capacity must be selected for the actual system, not inferred from the case size.
Frequently asked questions
Is this an MPPT model?
This listing is for the PWM version shown in the photographs. Request separate confirmed specifications if you need a different charging configuration.
Can it charge lithium batteries?
The catalog lists LiFePO4 and lithium-ion as supported battery types. Set the charging and disconnect thresholds for the battery requirements; the default voltage values are not suitable for every lithium pack.
Does 100 V VOC mean a 100 V battery is supported?
No. The battery systems listed are 12 V, 24 V, 36 V and 48 V. The PV open-circuit limit is a separate specification.
Can it be installed outdoors without a cabinet?
The listed protection is IP21. Use an installation arrangement that protects the unit from weather and maintains the specified temperature range.
What information is needed for a distributor quotation?
Send SY4860A, order quantity, battery voltage and chemistry, panel electrical specifications, load requirements and destination market. Ask for confirmed pricing, sample availability and delivery terms.
Product inquiry
For SY4860A supply, share the electrical requirements and quantity so the configuration can be checked before quotation. Branding, packaging, MOQ and lead time are confirmed for the order.
Request SY4860A specifications and a quotation